top of page

Loading...

Placeholder.png

MARBLEISED

Product Details & Specifications

Polysales

POLYFLOR EC

PVC

POLYFLOR EC

The product specification has been sent to your account email address. 

An error occurred when sending your specification through. We've been notified and will look into the problem. Please try copying and pasting the specification.

Supply and install Polyflor EC flexible PVC sheet flooring with electrostatic conductive properties in [Black/Grey] [2.0] mm thickness, homogeneous and monolayer in construction, the electrostatic conductive properties must be present throughout the full product thickness, the flooring shall conform fully with the requirements of EN 649/ISO 10581, in respect of flame spread, the flooring shall have been fully tested to EN 13501-1 and certified as having Class Bfl-S1, achieving the criteria EN ISO 9239-1 ≥8kw/m2 and the mandatory requirement of EN ISO 11925-2 pass. It shall be tested to ASTM E648 and certified as having passed with a Class 1 rating, making it suitable for use in institutional, commercial and public buildings, with regard to EN 13893 for slip resistance, the flooring shall be classified DS, making it suitable for use in areas which are predominantly dry, but with occasional spillage, the product must have been fully tested for abrasion resistance to the Frick Taber test EN 660: Part 2 and be in abrasion group M, as defined in EN 649, with regard to electrostatic conductive properties, the flooring must conform to the requirements of HTM2. Tested to ASTM F150 the flooring must have a resistance of between 2.5 x 104 to 1 x 106 ohms. When tested to EN 1081 R1/R2 the flooring must have a resistance of between 5x104 to 1x106 ohms, when tested to ESD S7.1, the flooring must have a resistance of between 5x104 to 1x106 ohms. Tested to BS IEC 61340-4-1 2003 Rg, the flooring must have a resistance between 5x104 to 1x106 ohms. When tested to BS 2050 the surface resistance and resistance to earth should be between 5x104 to 2x106 ohms, when tested to BS EN/IEC 61340-4-5 the flooring must have a resistance of <1x109 and chargeability <100v, in accordance with EN 649, the in-use classification must be at least 34/43 as defined in EN 685: i.e., commercial areas with very heavy use; and light industrial areas with heavy use, the flooring must be available in 2.0 metre width, to minimise the number of joints, in respect of light fastness, the flooring shall have been fully tested to ISO 105-B02 Method 3 and obtain ≥6

Project References

NO PROJECTS AVAILABLE

NO PROJECTS AVAILABLE

NO PROJECTS AVAILABLE

NO PROJECTS AVAILABLE

NO PROJECTS AVAILABLE

NO PROJECTS AVAILABLE

bottom of page